Sunday, October 24, 2010

DIL SINEWAVE UPS / INVERTER

DIL SINEWAVE UPS : UNIQUE FEATURES
  • Pure Sine Wave Inverter less 3% THD (Total Harmonic Distortion)
  • Based on DSP cutting edge Technology.
  • An Attractive and a very compact design to be part of your living room.
  • In built SMPS based charger with power factor correction to minimize the Power loss.
  • Constant 220v Out put voltage at any instant and at any load.
  • Mains Input output wrong connection protection.
  • Automatic Battery health check up and Bad Battery Detection by Battery intelligent software.
  • Visual indication with an Attractive LCD indicating load percentage, Battery voltage and Input output Voltage.
  • Suitable for solar charger.
DIL SINEWAVE UPS – RELIABILITY
  • Over load and short-circuit protection: It has overload / short-circuit current limiting and cut-off, the control part of the Inverter will sense the output current and if the load is more than the rated VA, for example: In a 1000VA Inverter, if you accidentally connect a load of 2000VA, it will limit the output current to the maximum output current at full load of the Inverter.
  • High & low input voltage cut off: The high input voltage cut-off is set for 260V (it can be set for some other voltage also) up to 260V input, the output will be 220V. Because of this high voltage cut-off, the Inverter itself will be protected from high voltage and the connected load is also safe. The low voltage cut off can be set at any value. For example – in a 170V to 260V model, the low voltage cut-off can be set at 170V or lower. Because of this low voltage cut off, the Inverter is protected from low voltage malfunctioning & automatically go to Inverter Mode, thus load connected is safe & uninterrupted.
  • Intelligent Battery Charger: Advanced DSP Based PWM SMPS & Intelligent Charger Circuit enables the full protection for the Battery, this protects the Battery from Under charge, Over Charge, Full Charge, Deep Discharge
  • Digital LCD Display: This is the Exclusive user-friendly feature in our Inverter / UPS, this will display all the parameters like => Mains On, => Inverter On, => Batt Low, => Overload, , => Battery discharge, => Battery Charging, => Battery Full. Accordingly one can easily know what’s going on & can monitor the Status of Working.
  • => Machine Fault, => Call Service, these are all the Error Codes displayed in case of any fault in the system, this in turn helps in rectifying & trouble shooting the Problem or the Fault in the Inverter / UPS.



No comments: